Nov 05, 2019 · In most cases, the flue is horizontal, and it can be seen coming through the exterior wall on the side of the building. With a horizontal flue, the pipe travels straight through the wall behind the boiler. In cases where the boiler is not …
Get priceNow some boilers are accessed from the sides via little cast iron plates, use rust buster on the bolts and they should come off. Make sure that everything is furnace cemented shut again, no excess air through cracks. Put the whole works together and check the flue for excess CO, if you have it, the boiler is toast.
Get priceSep 03, 2019 · The boiler's been out of action for a few days so there hasn't been any heat to drive off this moisture. There was torrential rain here overnight, and so I'm wondering whether this is rainwater coming in. The boiler has the standard horizontal flue option, i.e. one 90 degree bend then about 300mm of flue going straight through the wall to
Get priceAug 11, 2007 · The flue on a condensing boiler is supposed to pass thru the wall with the angle of the fall running back towards the boiler so that condense created by the boilers operation is collected in the boiler before being discharged. It sounds like the flue has been set to fall in the opposite direction hence the effect you explain. Hope This Helps
Get priceDec 02, 2007 · I see new boiler instalations with balanced flues,these are now very small, but with a powerful fan, I have a combi gas boiler with a flue through the wall,if its very cold it will flow steam around a bit, no problem really. But some of the new gas balanced flues i notice blow the steam together with particles a good distance.
Get priceA boiler that is leaking water isn't a good thing and, if left, can lead to further problems. Usually, it's just a sign that a seal or a valve has developed a fault, however when left, it can cause other components to rust and can even damage the electrical components within the boiler.
Get priceNov 23, 2013 · You need at least 150mm from the window to clear the lintol bearing (structural) although i've seen lintols hanging on an by a inch. If you are measuring 100mm from the window taking a straight line from the centre of the boiler flue you can easily get more than 150mm by angling it by a couple of degrees then fit a plume kit.
Get priceFeb 03, 2018 · hi, i've just moved into a 1 bedroom house, my neighbor has a boiler installed right next to my bedroom window the flue is so near my window i think the boiler is resting or very near the boundary wall, also the noise it makes my entire …
Get priceJan 08, 2010 · Odd thinks I, so switches everything back on at the consumer unit, goes back into the house to find a flooded kitchen and a considerable amount of water dripping from underneath the boiler. Thought this was due to something in the boiler breaking, but in fact was due to how the condensate pipe is fitted, and the current cold snap.
Get priceNow some boilers are accessed from the sides via little cast iron plates, use rust buster on the bolts and they should come off. Make sure that everything is furnace cemented shut again, no excess air through cracks. Put the whole works together and check the flue for excess CO, if you have it, the boiler is toast.
Get priceThe answer to does the manufacture instruction override the gas fanned flue from being too close to the window, then the answer to this is yes but the correct instructions must be of that the exact boiler has to be present for the gas safe registered engineer to see and to record. As the gas engineer is responsible, it also has to be classified
Get price6t boiler Factory Price Singapore - balloons2send.co.uk. Gas steam boiler about 15 tons price Industrial Boiler. Steam boiler . 12- 15 ton steam boiler used machinery 12 ton package steam preferably smoke tube 3 pass package type or fbc or water wall type working pressure mininum 250 psi or 17.54 kg/cm2 husk--wood- baggase fired should be on
Get priceFeb 11, 2021 · Within the first month after installation we had water coming out the bottom of the boiler, this appeared to be from rain coming through the air intake. After that, we've had some awful vibrations coming from the boiler, which don't appear to follow any pattern, sometimes they've lasted a few seconds, sometimes longer.
Get priceJul 16, 2009 · That will turn it slightly away from rain without turning it directly onto the roof. (flue gas is highly acidic) If it's a metal flue, than the top of the flue should have a "storm cap" on top of the flue, with a "storm collar" below the cap and above the roof. The storm cap keeps water from getting into the flue, and then making it
Get priceDuring heavy rain, our boiler leaks water out the bottom. I think rain must be getting blown into the flue – is this a big deal? I mean aside from being a pain in the aris having a leak, is it
Get priceNov 03, 2013 · Mgmgnt company have sent letter to all flats saying flue outlet pipe installed the wrong way round. Full version of events: As a quick reminder, the type of flue which was installed was was the wrong type for the boiler, and the flue ended up melting, no support structure in place so it fell back through into the roof.
Get priceJun 28, 2010 · My boiler is a Glow worm, Fuelsaver 30B Mk II. Its around 20 years old and is serviced regularly by British Gas. Last year when we had heavy driving rain against the wall of the house, on 3 occasions rain started coming in through the flue and running down the kitchen wall behind the boiler onto the work top.
Get price2 Ton Factory Price Steam Boiler Industrial. 2ton boiler factory price Coal Fired Boiler Manufacturer With more than 30 years of manufacturing boilers the company has formed more than 400 varieties of China Factory Price 1 Ton 2 Ton 3 Ton 4 Ton 5 Ton 6 1 ton 2 ton per hour steam boiler price Alibaba.com
Get price10 Ton Gas Boiler Machine Industrial Manufacturers Ukraine. Yongxing is a top-level steam boiler manufacturer in China. We have around 40 years experience on supply you best steam boiler system. Guaranty steam boiler factory price. Yongxing oil / gas boiler efficiency get to 98%, Coal / biomass boiler efficiency 85%+.
Get priceWater coming in flue pipe after boiler installation
Get priceHole was smaller than pencil eraser. For anyone with a suspicion, if you can hear hissing that sounds like a water running through a faucet. If your regular op pressure is low, and you suspect a hole in the boiler, raise the trol pressure up for a cycle and …
Get priceJan 30, 2021 · I've seen water run down the brick wall and into the boiler, also see rose bushes growing round the flue causing water to run inside. if it was a split flue, I mean split enough for a lot of water/condensate to pass from inner to outer, then the burn would be bad, recirculating flue gasses which the BG guy would pick up on straight away
Get priceJun 11, 2009 · The flue comes out of the top of the boiler, then turns and goes horizontally out through the wall. It's about 2-3 feet from the top of the boiler to the end of the flue. The fault would probably not have happened if the flue sloped downwards as it went outside - in fact it is possibly slightly upwards but it's hard to tell as there is no space
Get priceNov 09, 2008 · I asked recently about rain ingress as my new boiler has been fitted with a flue that points upwards, about 5 degress from horizontal, which to my mind is bound to see some rain come in. It was pointed out (helpfully by most!) that that is the right way to fit the flue for the boiler that I have (of course, others may be different).
Get priceNov 17, 2016 · Boiler flue flashing leaking the flue, but he hasn't pushed it through properly so the rubber is doubled up where it meets the flue and a …
Get priceOf the make up water to the boiler is off, and the boiler holds pressure the system is not leaking. Is it possible since you noticed water coming up through cracks in the slab that water from the shower is going into the slab with no where to go.
Get priceWater coming in flue pipe after boiler installation
Get priceAug 06, 2013 · Boilers - Home Heating Steam and Hot Water Systems - Boiler goes above 30 psi - tried several things - still problematic - Hello all, I'm new to the forum and have been reading and searching and can't find a solution to my problem. Here is the situation. I have a Weil-Mclain CGM-4, series 7 water boiler heater. For
Get priceOct 12, 2011 · 11 October 2011 at 10:49PM edited 13 October 2011 at 10:02PM in In My Home (includes DIY) MoneySaving. I have seen this in several houses. I assume it is for combination boiler. On the outside wall below the flue/exhaust outlet of the boiler is a copper (15mm?) water pipe which is a simple u-bend sticking out as if checking the outside temperature.
Get priceRain Leaking Through Flue & Onto Boiler | PlumbersForums.net
Get priceJun 29, 2017 · As the exhaust part of the flue sticks out further than the outer part, rain was hitting the exposed part then running down underneath and …
Get priceA simple way to avoid this from happening is by fitting an external air break into the pipework (see picture below) before it enters the vertical rain water pipework. This separates the condensate outlet of the boiler from the drain pipe. This makes it impossible for water to flow back into the condensate pipe, even if it becomes blocked.
Get priceRainwater got into boiler down the flue | DIYnot Forums
Get priceOct 12, 2011 · 11 October 2011 at 10:49PM edited 13 October 2011 at 10:02PM in In My Home (includes DIY) MoneySaving. I have seen this in several houses. I assume it is for combination boiler. On the outside wall below the flue/exhaust outlet of the boiler is a copper (15mm?) water pipe which is a simple u-bend sticking out as if checking the outside temperature.
Get priceDec 02, 2010 · Nov 29, 2010. #6. didnt understand the last post but the flue should be sloping 3 to4 degrees back to the boiler so that all condensate goes back into the boiler to exit via the condensate drain and not drip out of the flue.max flue length for a 60/100 flue on a 28 combi is 6metres dont forget to deduct 1.4metres for each 90degree elbow though. P.